Knowledge Hub

Filter Knowledge Posts by:

Diesel Generator Acoustic Enclosures: An Engineering Guide

Diesel generator enclosures are often treated as simple housings, but real-world performance depends on far more than a fabricated shell around a set. This guide explains what an enclosure is actually required to do in practice, from noise control and cooling airflow to structural logic, access, leakage control, package boundaries, and evidence ownership. It is designed to help consultants, contractors, specifiers, and end users understand the engineering decisions that determine whether an enclosure performs reliably on site.

Read more

AHU Refurbishment Decoded: How to Decide, What to Upgrade and How it all Works

Air handling units seldom fail overnight; performance drifts, energy rises and compliance pressure grows. This guide explains what refurbishment involves, from condition surveys and specification choices to commissioning and verification. Use it to plan upgrades with confidence, reduce disruption and deliver measurable gains in reliability, efficiency and indoor air quality.

Read more

AHU Decarbonisation: The Complete Guide

Air handling unit decarbonisation is no longer a marginal consideration; it is a regulatory, operational and environmental imperative. This guide presents a technically rigorous roadmap for reducing the carbon impact of AHUs, from EC fan upgrades and thermal wheel retrofits to system-wide efficiency modelling that supports Net Zero strategies.

Read more

The Ultimate Guide to HTM 03‑01 and Compliance for Ventilation Systems

HTM 03 01 is the UK’s authoritative technical standard for the design, installation, operation, and maintenance of ventilation systems in healthcare premises. Published by the Department of Health, it defines minimum requirements for performance, hygiene, reliability, and energy efficiency to ensure that indoor air quality supports clinical safety and patient wellbeing

Read more

FAT & SAT Testing for Air Handling Units (AHUs) – What You Need to Know….

FAT and SAT are critical steps in ensuring your AHU performs exactly as specified , both before it leaves the factory and once installed on site. This guide explains the purpose, process, and standards behind both tests, and how Mansfield Pollard supports every stage.

Read more

The Ultimate Guide to Commercial MVHR / Heat Recovery Units

MVHR stands for Mechanical Ventilation with Heat Recovery. Sometimes MVHR units are referred to as Heat Recovery Units (HRU’s) or Commercial Heat Recovery Units. The process is sometimes referred to as Heat Recovery Ventilation or comfort ventilation.

Read more